Technical Specification
INPUT | |
Voltage AC | |
Direct voltage AC | 30 to 300V (L - N) 50 to 520V (L - L) |
Primary PT Ratio | 100V to 520KV Selectable |
Secondary PT Ratio | 100V to 520V Selectable |
Burden | < 0.2 VA |
Current AC | |
Primary CT Ratio | 9999A Selectable |
Secondary Current Ac | 5A or 1A |
Burden | < 0.2 VA |
Overload | Upto 6A Continuous |
Frequency | 45.0 to 65.0 Hz |
DISPLAY, KEY & LED | |
Display | 3-Digit, 3-Line, 7-Segment, 0.59” RED LED |
Key | Set/Ent, Inc, Dec/Scroll |
LED Indication | A, KA, KV, VLL, VLN, Avg, HZ, L1, L2, L3, PS |
DIMENSION | |
Size (mm) | 96 (H) x 96 (W) x 43 (D) |
Panel Cutout (mm) | 92 (H) x 92 (W) |
CALCULATED PARAMETERS | |
Voltage | VLL, VLN, Avg. |
Current | All Phase Amp, Avg Amp |
Frequency | System Frequency |
Load hour | Upto 9999 Hr 59 min |
RPM, Phase Sequence Indication | |
ACCURACY | |
Class 0.5 (Standard) | |
AUXILIARY POWER SUPPLY | |
Power Supply | 100 to 270V AC/DC,50/60Hz |
Burden | 4VA |
ENVIRONMENTAL CONDITION | |
Working Temperature | 0 to 55°C |
Storage Temperature | 0 to 55°C |
Relative Humidity | 95% RH Non-Condensing |
Protection Level ( As per Request ) | IP-65 (Front side As per IS/IEC 60529 : 2001) |
Application
Product Variant
Model | Voltage | Current | Auxillary |
AVF-19T-E3-N0 | Network Selection :3Ø3W/4W, 1Ø2W PT Primary: 100V to 520kV (Programmable) PT Secondary: 100V to 520V (L-L) (Programmable) | CT Primary :Upto 9999A CT Secondary : 5A | 100 to 270V AC/DC |
3Ø -3W/4W, 1Ø-2W Selectable3-Digit, 3-Line, 7-Seg, 0.59” RED LEDPrimary CT Selectable upto 999... Continue
3Ø-3W/4W, 1Ø-2W Selectable3-Digit, 3-Line, 7-Seg, 0.59” RED LEDCT Primary Selectable Upto 9999... Continue